<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-04 00-08-27
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
97.30 MHz 5/5, 76 dBuV YLESUOMI
Pilot RDS Phase Difference
7.0 kHz 3.7 kHz 70 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 66 kHz 19119 3,7136
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,4 dBr 3,95 dBr 5,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLESUOMI" 6203 10 (Pop M) 1 0 1 1 0:08, 4.05.2025
RT
"ULTRAVOX - Dancing with tears in my eyes "
AF EON
95.6, 97.3, 98.4, 98.6, 98.9, 99.2, 102.5 MHz 6205, 6201, 6202, 6207
FM Scope Max at: 66 kHz MIN: 10 kHz % above 76 kHz: 3,7136 Acquired: 2025/05/04 0.07.23 Total samples: 19119 Equivalent time: 0:15:55 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 5,3 dBr MIN: 1,4 dBr AVE: 3,95 dBr % above 12,2 dBr: 0,0 Last value: 1,5 dBr (2025/05/04 0.07.22) 23.54 23.56 23.58 00.00 00.02 00.04 00.06 0 2 4 6 Pm [dBr]